How Building Orientation Can Help Curb Power Consumption in Commercial Buildings

Commercial buildings are not the bad guys. We need them all the time. They provide a sizeable proportion of our urban needs and services, but commercial buildings typically consume a large chunk of urban power. Studies in America have shown that the power consumed in commercial buildings account for up to 30 per cent of the total electricity consumed annually.* Reducing power consumption in commercial buildings is one of the prime objectives of green architecture, and in the last several years, various approaches have been formulated on how to achieve this. One of the more basic means to do so is to plan a building’s orientation to optimise heat gain in relation to the sun’s path and consider wind direction, thus reducing the heating/cooling load on power consumption, increasing the efficiency of building services. With the right HVAC mechanical engineering consultants and electrical design services working on an intelligently oriented building, a significantly effective energy-efficient building design can be formulated.



When we talk about commercial buildings, we refer to office buildings, hotels, hospitals, shopping malls or other buildings used for retail. In general, these buildings are multistoried and use power continuously throughout the day and sometimes through the night, contributing to greater power consumption.

Typically, commercial buildings are oriented to make the best use of street appeal, view scenic surroundings or for drainage considerations, but skyrocketing energy costs mean that designers and builders must attempt to incorporate the benefits of free solar energy into building design, with the result of reducing carbon footprints and increasing the building’s marketing value. At the same time, occupants experience the same, expected indoor comfort with reduced energy bills.

The orientation of a building affects the heating, cooling, lighting, daylight access, ventilation and views of occupants. Variations in the usage of power is determined by solar gains impacting cooling and the effect of daylight affecting the use of artificial lighting. Considering climate, low-E coatings on glazing can regulate solar heat gain. Cold climates may need passive solar gain, while hot climates may need a reduction in solar gain.

Orientation towards certain directions is advantageous during some climates. In cold climates, buildings-oriented west of north will result in increased solar gains in the afternoon, and buildings-oriented east of north will be warm during the mornings. At locations with warm climates, buildings-oriented east of north will be better positioned to capture cooling breezes. In commercial buildings, therefore, it must be determined early in the design stage when more warmth would be beneficial, depending on occupancy rates.

For commercial buildings in the Northern Hemisphere, orientation towards the sun requires the largest side of the building to face south and have the most windows, as the sun rests longer on a building’s southern walls. When windows face east or west, they allow the entry of excessive heat, making air conditioners work long and hard during the summer. They also cause issues with glare in commercial buildings. During winters, maximum exposure to daylight provides passive heat, reducing HVAC system dependency.

It’s easy to see that building orientation is ideally based on the geographical location of the building and the local climate for most of the year.

Orientation for Passive Cooling

When commercial buildings are oriented well and decisions are taken to incorporate landscape design and shading elements, passive cooling can be achieved fairly simply. Proper orientation can exclude bright, hot sun and hot winds while accessing cool breezes in certain climates. Hot, humid climates should ideally have buildings that are protected from direct sunlight and heat from nearby buildings (radiant heat). This can be achieved if landscape and adjacent buildings funnel beneficial breezes and shading is provided to all or most external walls.

How the sun travels, or its solar path, influences a building’s heat gain to a large extent. Intelligent building orientation can be crucial in passive solar construction. According to research, a ridgeline running east-west on a rectangular building is ideal. This will maximise the length of the southern side of the building, and several windows on the south will help. Due to the intensity of the summer sun, the northern side of the building ideally should have fewer windows. Of course, directions should be considered as a solar reference and not magnetic north, which varies considerably.

So, what really happens on the sun’s path?

The Truth about the Sun’s Path

Every child will tell you that the sun rises in the east and sets in the west. If we want to be strictly accurate, this happens only on 2 days of the year, the autumnal and vernal equinoxes. During the rest of the year, things are slightly different. The Earth’s tilt on its axis means that the sun rises and sets slightly south of east and slightly south of west during the winter, and slightly north of east and slightly north of west during the summer. The angle is slight and depends on the season and how far the observer is from the equator.

What this means is that the winter sun lives in the southern sky and the summer sun lives in the northern sky, in general. For those living in the Southern Hemisphere, these directions are reversed, which means that for those in Oceania, most of South America, almost half of Africa and some parts of Asia, the winter sun rises in the northeast and sets in the northwest, and the summer sun rises in the southeast and sets in the southwest.

Confusing? Not really. Building engineering designers and architects need to consider these directions, locations and seasons for best results.

Having a south-facing orientation results in shading from the summer sun, reducing solar gain but still accessing sufficient daylight to reduce energy loads associated with artificial lighting. Summer sun angles are high, while winter sun angles are low, enabling the easy entry of light and heat to a building. When buildings are oriented to the north as well, they receive sufficient amounts of indirect daylight, and solar gain, direct light and direct glare are reduced. These factors are more difficult to control if building facades face east or west, as they will then deal with the full intensity of the rising or setting sun, respectively.

In addition to the solar path, building orientation can also harness wind movement for optimum results, even having the potential to utilise wind turbines to generate power. Also, winds and wind patterns can help regulate heat gain. Prevailing winds in a geographical area are winds that blow predominantly from a certain general direction over that location. Studying, analysing and calculating wind data for certain locations can help design commercial buildings that can use summer breezes for passive cooling or protect the interiors from strong wintry winds. These calculations can even possibly prevent the pile-up of snow outside entrances.

In general, chilling winter winds originate in the north and the west. For coastal areas, breezes typically originate from onshore directions, and cold breezes blow down from the mountains to the valleys. Insulated glazing on the building’s sides can limit the effects of these winds.

What happens when builders are unable to choose building orientation?

Building orientation must be fixed on certain plots, especially if they are commercial buildings. The orientation cannot be chosen or planned. If the climate is hot and does not require heating, the site can be developed so that surrounding buildings and trees shade the walls and can channel cool breezes inside.

Excluding photovoltaic collectors and areas deliberately exposed for solar power generation, roofs can be shaded as much as possible. Windows facing east and west should be minimised or eliminated, and those that can’t be avoided should be well shaded. Unwanted heat enters through unprotected glass, so shading the glass can reduce heat gain.

Tips to Regulate Heat Gain through Orientation

Sometimes, builders can use these simple tips to regulate heat gain, depending on the climate:

  • Solar-oriented floor plan – Individual floor plans in multi-storey buildings can face the sun for maximum heat gain.
  • Tall trees for shade – Evergreen trees on the north side of the building will provide shade during the summer. However, trees can pose certain dangers, so builders must consider age, species, growth rate and canopy cover before deciding to plant new or retain existing trees on the building lot.
  • Sufficient number of windows – Too many windows can drain heat from the interior during the winter, and they can allow the entry of more heat to the interiors during the summer. 
  • Angled glass – It’s not always necessary to have vertical glass. When glass is sloped to match the sun’s angle, reflection can be minimized. Insulation effects are reduced with angled glass, but possible solar gains need to be balanced with heat loss to the outdoors. 
Currently, software tools can accurately calculate location-specific solar gain and seasonal thermal performance. They can rotate and animate 3D graphical models of commercial buildings with regard to the solar path.

Though street appeal and lot dimensions may ultimately limit a building’s orientation to benefit from passive solar approaches, innovative designs by HVAC mechanical engineering consultants and efficient electrical design services can result in operational energy reduction. Commercial buildings will use less energy for heating and cooling, curbing power consumption, if they are properly oriented according to their geographical location and climate. This will then result in lower power costs without compromising indoor comfort.

Tuesday, December 25, 2018

Design HVAC for Modern Office Facility

Much like office practices and workflows, modern offices are changing. They are designed to be more open than in the past, which consisted of a ring of private cabins or offices surrounding clusters of cubicles in the centre of the office floor. The open plan design calls for alternative considerations for heating, ventilation and air conditioning, or HVAC duct design.

Cubicles are increasingly replaced with workspaces created for specific activities, such as team lounges, fitness centres and large work tables for discussions and collaboration on team projects. The HVAC system consumes a significant portion of all energy needs in a building, and changes in the office layout will impact the HVAC design. Thinking and planning for HVAC design in an office space needs to begin as early as possible when considering renovation or a new project to save energy costs.



Design goals for office buildings are based on the fundamental principle of ensuring health and safety to those occupying those buildings. Ventilation, therefore, is required at all times and must eliminate or minimise pollutants. The measure of air flowing in or out of a space is cubic feet per minute or cfm. Generally, a person needs up to 30 cfm of outdoor air, and an ideal comfortable temperature is between 20 and 24ºC with 20-60% relative humidity. The efficiency of HVAC systems design makes these conditions possible.

Some of the key strategies for efficient HVAC systems design in modern offices include:

Reduction of Cooling Loads

Well insulated walls, floors and windows are a must. The use of natural light for a healthier workplace is becoming increasingly accepted as the norm and for the reduction of heating loads during the winter season. For warmer climates, tinted low-e glass can help avoid solar gain (solar heat gain or passive solar gain), which is the increase in thermal energy resulting from the absorption of solar radiation, and reduce cooling loads. Low emissivity glass, or low-e glass has a super-thin transparent coating that reflects infrared energy or heat. This glass minimises both ultraviolet and infrared light passing through it without affecting the visible light that is transmitted.
Lights that automatically switch off during sufficient daylight conditions are a useful energy-saving idea, which can work as a complement to cooler lighting options and will generate less heat, thus reducing cooling loads on the HVAC system.

HVAC System Size

It’s important not to install an HVAC system that is too big for the energy needs of the office concerned. Oversized air conditioning systems typically create discomfort during the day. Such systems generally switch on and off continuously and are not efficient in removing humidity, resulting in an office area that is predominantly humid and dotted with hot and cold spots. More than just square footage needs to be considered in calculating HVAC load requirements. Computer simulation can accurately analyse building materials, daylight, lighting design and space activities affecting HVAC loads.

Zones

Multiple zones with independent temperature controls within a large open space translates to greater efficiency and comfort. Different areas in open spaces have different temperature requirements, such as:
  • Perimeter areas, which need separate controls, as they are more susceptible to weather
  • Computer rooms, which have special temperature needs and controls
  • Conference rooms and other areas that host large gatherings of employees, which need more cooling while in use and less when empty 
Modern offices with fewer internal walls make these design details tricky.

Sensors
Smart buildings use sensor technology, mainly with two types of sensors – light sensors and occupancy sensors. These can be incorporated with HVAC design early in the design stages. Light sensors sense the amount of daylight available and adjust lighting accordingly. They can be connected to the HVAC system to maintain heating and cooling. Occupancy sensors track the number of people in a given space at a given time. They communicate with HVAC controls to regulate temperatures. During a large meeting, for example, occupancy sensors help increase cooling for the area concerned.


A ‘Sensible’ Option
Environmental sensors lead to cleaner, healthier air. Sophisticated sensors provide real-time data on air quality, revealing the surprisingly unhealthy current conditions of most offices worldwide and a related reduction in productivity. Studies show that a 670-sq ft office with 15 employees can generate CO2 levels of 1,000 parts per million (ppm) in under 8 hours. This is equivalent to 2.5 times atmospheric carbon dioxide levels and at a level that may cause 15% decrease in cognitive performance in employees. Meeting and conference rooms, naturally, are even worse, with 3,000 ppm, significantly decreasing productivity.
Organic compounds from furniture and carpets combine with these high levels of carbon dioxide to increase fatigue in employees and decrease productivity. In some cities, windows cannot be opened due to the toxicity of the smog outside. Indoor air quality could be improved with HVAC systems that react to carbon dioxide and airborne particles. This could be achieved by pulling in fresh air and filtering out pollutants.


Under-floor Air Distribution
Typically, air conditioning cools a space using overhead air distribution. This method may not be ideal and less energy efficient in open spaces with high ceilings. Use of under-floor air distribution is a popular trend today. Diffusers are installed under a raised floor, transmitting cool, air-conditioned air throughout the space. Stratification moves warm air upwards to the ceiling and cooler air-conditioned air replaces it at ground level. This method has been found effective in providing continuously comfortable conditions and maintaining better air quality.

Ventilation
An effective HVAC design must control humidity, eliminate odours and remove dust, carbon dioxide, bacteria and viruses that may contaminate the space and spread illness. In an open-plan office, this is critically important. The correct indoor air quality must be regulated and maintained for the well-being of employees and their productivity. Sufficient intake and distribution of outside air and the controlled circulation of conditioned air is a mandatory requirement of efficient HVAC design.

Experts’ Design
Whether renovating or creating from scratch, professionals from the field, such a HVAC mechanical engineering consultants, must be taken on board right from the early stages to avoid costly errors at later stages. Consultants will utilise their professional HVAC design and drafting skills to produce high quality HVAC shop drawings, which can then be coordinated with other trades.

Open Windows
Decades ago, offices had windows that could be opened. Currently, most offices worldwide are air conditioned and air tight. Windows that can be opened help control energy consumption and give people greater control over their work environments. But skyscrapers with offices don’t have windows that open or have access to fresh air during a work day. Why? Well, some of the reasons for permanently closed windows are:

  1. To prevent cooled, air-conditioned air from escaping and unfiltered air, noise, rain and insects from entering
  2. That offices are wary that people may fall out or jump out, resulting in the offices and management being held responsible
  3. That some employees may open windows on a hot day, making the air conditioner work harder
  4. That in keeping with modern architecture, open windows are unfashionable and they disturb the lines of the building
  5. That with many employees on any floor, natural ventilation is near impossible
  6. That energy is saved, increasing productivity

Facts show that these concerns are no longer concerns. A naturally ventilated, intelligently designed office building can halve the energy consumption of constantly air-conditioned buildings. A naturally ventilated building need not support intense and constant HVAC system needs. Ventilation that is natural and access to fresh air contributes to an increase in productivity. A connection to the outdoors, a perception of control and better overall health are beneficial side effects of natural ventilation. The design of HVAC systems in an office facility thus has a direct bearing on the productivity of the office’s inhabitants.

With the help of qualified and experienced HVAC mechanical engineering consultants, a comfortable, safe and secure office building may be constructed with the right HVAC shop drawings. In the global environment of outsourcing MEP (mechanical, electrical, plumbing) design services, the quality, expertise and experience required can be found overseas, resulting in cost-effective, precise HVAC design and drafting.

Wednesday, December 19, 2018

The Challenges of Coordinating Risers

For modern buildings, risers carry the very life blood of a comfortable space. Much like an arterial system, different kinds of risers perform various necessary functions for the health of a building. They are conduits or carriers of fluids, fuel or air. Coordinating risers is critically important within the workflow of MEP coordination and clash detection, and this can be challenging at times. Challenges generally occur with hydraulic services design during renovation of older buildings. Let’s look at how that may happen.

Well, first off, what is a riser?



Also known as a vertical riser, a riser is a void that contains a duct, pipe or conduit or a combination of all services that rises through a building to carry or transport gases, fluids or electrical signals in the form of piping. In general, a dry riser is an empty, or dry, pipe used to carry water for firefighting systems, and a riser cable can deliver electricity or communications between several floors. Looking at risers in more detail, they can be:

1. Vertical Riser Ducts
As mechanical pipes and electric cables are aesthetically unappealing, typically they are hidden away in vertical riser ducts. These ducts must be strategically placed to minimise pipe lengths and cable runs, thus cutting costs. Pipes must run unhindered vertically in ducts, especially sanitary waste pipes, so that this waste water need not navigate bends in pipes. Since vertical risers cut through floors and can be vulnerable for the spread of fire, they must adhere to strict guidelines.

2. Vertical Riser Cables and Pipes
Sometimes, it is practical to have risers exposed. Servicing becomes easier. Cables connect to sockets and light fittings to riser conduits mounted on walls and columns. Cables and pipes that travel through floors are covered with fire-protected collars, to prevent the spread of fire through them. Increasingly, services pipes are becoming part of the décor.

3. Wet and Dry Risers
Vertical pipes, that are both wet and dry risers, run the full height of a building and are built near stairs to provide a direct water feed to each floor in case of fire. Dry risers have ground coupling pipes outside the building that can be connected to an external water source in case of emergency. Wet risers are connected to the building’s water supply.

4. Dry Risers in Fire Fighting
A dry riser usually includes the following:
Inlet Box

  1. Made of galvanised sheet steel, for recessed mounting, with architrave
  2. Has a hinged, lockable door with a panel glazed with wired glass, so that the lock can be opened after breaking the glass. 
  3. Hoses can be connected to inlets without opening the door.
  4. Large enough to access for maintenance and operate the drain valve
Inlet Breeching
  1. A two-inlet breeching, with instantaneous male coupling, back pressure valve, blank cap and chain
  2. Has a gunmetal gate valve for drain purposes, with plug and chain
Landing Valves
  1. Straight or oblique gunmetal gate pattern valves, with flanged inlet, instantaneous female outlet with blank cap and chain, fixed with a leather strap and padlock
  2. Lined and coated with woven synthetic fibre hose and diffuser branch pipe nozzle
  3. Valve, hose and nozzle in a box, on purpose-made hangers
Air Release Valves

  1. Brass automatic air release valve, with a rubber ball inside
For a tall building with the same floor layouts (e.g. apartments), the riser equipment/elements will change size as they move down or up the building. As such, a section of each riser will show slightly different sizes, especially for ductwork, which is why a drawing is created for every floor, even when the rest of the floor is the same.

With a variety of risers to deal with in the MEP (mechanical, electrical and plumbing) sector, it is crucial that the MEP systems coordination workflow, especially with regard to hydraulic design of liquid or water piping systems, is efficient. Technological advances and the innovations they enable have been a prime factor in fuelling this efficiency. In the construction industry, BIM (Building Information Modelling) has been driving immense change in the MEP coordination process and the delivery of MEP coordination drawings.

The use of BIM technology has made equipment tracking and task monitoring easier. Covering almost every aspect of a construction project, the BIM process involves project managers, subcontractors, designers, architects and other construction professionals participating in controlling individual processes and project phases, with a smooth exchange of information during the larger MEP coordination process.

Increasingly, the trend in the AEC (architecture, engineering, construction) sector is to design 3D models for 2D construction documentation and 3D trade coordination. Generally, the trade design or MEP design follows the architectural design stage. Trade professionals, such as HVAC mechanical engineering consultants and others, collaborate with architects to design mechanical, electrical, plumbing, fire prevention and fire protection services. A consultant or MEP contractor ensures that the MEP design is efficient, clash-free and installation-ready. At this point, fabricators who create ductwork or pipework components, electrical ladders or module sprinklers share their input. Thus, a fully coordinated 3D model is developed that can be used for clash detection.

Subcontractors (for the different trades) can virtually place systems as shown on detailed design drawings with individual elements, which include risers, offsets, hangers, conduits with required radius bends and cable trays. Other elements to consider include data communication lines, fire protection system controls and process piping.

At this point, challenges may arise, especially during the renovation of an existing structure. Some of the circumstances that may contribute to challenges in installation of risers include:
  • Riser replacement in an existing building – opening up walls creates a mess, dust and debris throughout the premises and destroys expensive decorative finishes that were lovingly installed. In older buildings, asbestos can be destroyed, as well as lead-based paint that has peeled off.
  • Existing plumbing risers may be difficult to handle after years of corrosion, because rust makes steel pipes brittle.
  • As hot and cold risers behind kitchens and bathrooms are replaced, tiles, cabinets and walls must be removed.
  • Risers must be replaced entirely or not at all, since new risers attached to old risers can break.
  • Accessing risers takes time and money.
Signs that risers need replacement are hard to miss. Upper floors will experience low water pressure. Debris will appear in the water – bits of corroded pipe in sinks, showers and bathtubs. Time is an indicator. Galvanised steel pipes last for about 50 years, accumulating scale and rust inside, while brass lasts for nearly 70 years. Copper pipes last even longer. Coloured water is a definite indication of rust and scale accumulation. Also, excessively hot showers are a result of clogged plumbing risers that reduce the flow. The need to replace existing risers during renovation introduces different kinds of challenges for coordination.

- For example, during the renovation of an existing building, one of the chase walls was opened, and a large conduit was installed inside a duct chase against an exhaust duct riser, causing a clash in the planned duct connection. A coordinated model showed ductwork and risers in the limited space and how their placement could be manoeuvred to avoid the clash, guiding the fitting of components to meet the design requirements.

- In another building, the floor-to-floor height was 20 feet, generally enough for ductwork and piping from air handlers to central core chases. In this case, a chilled water piping that was routed only 10 feet above the floor and close to the AHUs (air handling units) and supply and return ducts, next to the shafts, made for difficult coordination. Ductwork from 2 AHUs had to pass above the chilled water piping and between hanger rods. Coordinated design drawings showed a more efficient duct placement.

- Yet another example involved duct and pipe routing between an existing main electrical room and adjacent AHUs. The electrical room had floor-mounted AHUs right outside, and the adjacent AHUs had disconnect switches and variable frequency drives (VFDs). Coordinated MEP drawings and 3D modelling showed that the chilled water piping to the electrical room AHUs had to be moved, as did the larger AHUs and VFDs, allowing the ductwork and piping to be placed with the correct amount of clearance.

Easing MEP Coordination
Forming a key part in setting up and laying out design, MEP coordination is a key means to connect building elements and make the structure functional. Earlier during MEP coordination, drawings were overlaid and compared and spatial and functionals interferences, or clashes, were dealt with by multi-trade professionals. This method needed countless revisions before the finalisation of the coordinated drawings, but BIM processes changed all that. The BIM workflow involves a 3D approach and data-based reasoning to help MEP contractors plan, design and install equipment, including risers, efficiently.

Using BIM technology, a once-prolonged and tedious process fraught with delays, insufficient data and miscommunication, is now smooth and efficient. A building’s MEP systems are seamlessly integrated and coordinated with architectural and structural systems, creating clash-free models.

The placement of elements of MEP design, such as risers, can be intelligently designed and laid out. Tools, such as Navisworks, enable clash-free designs, with multi-disciplinary integration in one work environment. Flawless MEP coordination drawings are produced.

The Revit Solution
Creating a 3D model with Revit software enables easy coordination during design, and clash detection can be performed with Navisworks. So, early on in the design process, the model can be coordinated with architectural design and MEP design that includes risers. The models of new buildings and those of existing buildings will have differing degrees of efficiency, since existing buildings contain unknown elements, spaces and conditions which may not be represented in models.

The good news is that with BIM-enabled MEP coordination, most of the challenges concerning the design, layout and clashes of risers in MEP systems is eliminated and smooth coordination results. Those firms that find it difficult to provide hydraulics and plumbing design services and MEP coordination services may consider online collaboration and outsourcing, which is efficient, accurate and cost-effective, for the delivery of precise MEP coordinated drawings as part of the hydraulics and plumbing design services and MEP coordination services. Managers can retain full control of the project, resulting in faster delivery.